GXT5 — single-phase online UPS 750 VA – 20 kVA
Country: USA · Model: GXT5
Single-phase online UPS from 750 VA to 20 kVA at 230 V with double conversion. It powers servers, network equipment and edge nodes in racks and small server rooms, one family covering everything from a switch to a full rack.
- Power
- 0.75–3 kVA (2U), 5–10 kVA (5U), 16–20 kVA (9U)
- Voltage
- 230 V
- Type
- online double conversion, rack/tower
- Batteries
- VRLA, external battery packs
Technical specifications
| Power | 0.75–3 kVA (2U), 5–10 kVA (5U), 16–20 kVA (9U) |
|---|---|
| Voltage | 230 V |
| Type | online double conversion, rack/tower |
| Batteries | VRLA, external battery packs |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Chassis height grows with power. The 0.75–3 kVA models take 2U, the 5–10 kVA models 5U and the 16–20 kVA models 9U. Every version mounts in a rack or stands as a tower, so the same unit moves from a floor-standing office node into a server cabinet. Internal VRLA batteries can be backed by external battery packs for longer runtime, placed in the rack units below the UPS. Online topology keeps the load on the inverter with no transfer at mains failure, and the output sine wave does not follow input distortion.
How to choose
Choose the rating by real load, then reserve rack units for it and for any external battery packs. When the battery has to last longer between replacements, GXT5 Lithium-Ion at 1000–3000 VA uses lithium-ion cells with 2–3 times the VRLA life. If the node must keep running after a power stage failure, the modular APS at 5–20 kVA with N+1 is the redundant option. Loads that need galvanic isolation are better served by the 6 kVA GXT MTX+ CB with its built-in transformer.
Request a price and lead time
GXT5 — single-phase online UPS 750 VA – 20 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How many rack units does a 10 kVA GXT5 take?
The 5–10 kVA models take 5U, in a rack or standing as a tower.
What is the top rating of the single-phase GXT5 UPS?
Up to 20 kVA in a 9U chassis.
Can GXT5 runtime be extended?
Yes, external VRLA battery packs connect to the 230 V UPS.
How tall is the 3 kVA GXT5?
Models from 0.75 to 3 kVA fit a 2U chassis, mounted in a rack or standing as a tower.
Is GXT5 a true online UPS?
Yes, it runs online double conversion at 230 V, so the load stays on the inverter during mains failures.