GXT5 — single-phase online UPS 750 VA – 20 kVA

Single-phase online UPS from 750 VA to 20 kVA at 230 V with double conversion. It powers servers, network equipment and edge nodes in racks and small server rooms, one family covering everything from a switch to a full rack.

Power
0.75–3 kVA (2U), 5–10 kVA (5U), 16–20 kVA (9U)
Voltage
230 V
Type
online double conversion, rack/tower
Batteries
VRLA, external battery packs

Technical specifications

Power0.75–3 kVA (2U), 5–10 kVA (5U), 16–20 kVA (9U)
Voltage230 V
Typeonline double conversion, rack/tower
BatteriesVRLA, external battery packs
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Chassis height grows with power. The 0.75–3 kVA models take 2U, the 5–10 kVA models 5U and the 16–20 kVA models 9U. Every version mounts in a rack or stands as a tower, so the same unit moves from a floor-standing office node into a server cabinet. Internal VRLA batteries can be backed by external battery packs for longer runtime, placed in the rack units below the UPS. Online topology keeps the load on the inverter with no transfer at mains failure, and the output sine wave does not follow input distortion.

How to choose

Choose the rating by real load, then reserve rack units for it and for any external battery packs. When the battery has to last longer between replacements, GXT5 Lithium-Ion at 1000–3000 VA uses lithium-ion cells with 2–3 times the VRLA life. If the node must keep running after a power stage failure, the modular APS at 5–20 kVA with N+1 is the redundant option. Loads that need galvanic isolation are better served by the 6 kVA GXT MTX+ CB with its built-in transformer.

Request a price and lead time

GXT5 — single-phase online UPS 750 VA – 20 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many rack units does a 10 kVA GXT5 take?

The 5–10 kVA models take 5U, in a rack or standing as a tower.

What is the top rating of the single-phase GXT5 UPS?

Up to 20 kVA in a 9U chassis.

Can GXT5 runtime be extended?

Yes, external VRLA battery packs connect to the 230 V UPS.

How tall is the 3 kVA GXT5?

Models from 0.75 to 3 kVA fit a 2U chassis, mounted in a rack or standing as a tower.

Is GXT5 a true online UPS?

Yes, it runs online double conversion at 230 V, so the load stays on the inverter during mains failures.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.