IRIS+ / IRISRT / IRIS-RT / IRIS+L online UPS 1–10 kVA

Single-phase double-conversion online UPS units of the IRIS series cover 1–3 kVA (IRIS+, IRISRT) and 6/10 kVA (IRIS-RT, IRIS+L). Control is DSP-based and the output cos φ equals 1.0. They are installed for servers, in data centers, bank branches and telecom equipment.

Power
1–3 kVA (IRIS+, IRISRT), 6/10 kVA (IRIS-RT, IRIS+L)
Topology
online double conversion, DSP
Output cos φ
1.0
Efficiency
> 92% (1–3 kVA), up to 94% (IRIS-RT)

Technical specifications

Power1–3 kVA (IRIS+, IRISRT), 6/10 kVA (IRIS-RT, IRIS+L)
Topologyonline double conversion, DSP
Output cos φ1.0
Efficiency> 92% (1–3 kVA), up to 94% (IRIS-RT)
Parallel operationN+X (6/10 kVA)
Versionstower, rack/tower (RT)
FunctionsECO mode, EPO, cold start, frequency converter mode

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The smaller models have efficiency above 92%, while IRIS-RT at 6/10 kVA reaches 94%. The RT version can equally be mounted in a rack or stand on the floor; the classic tower is more convenient under a desk or in an electrical room. The 6/10 kVA models are combined into an N+X parallel system when the failure of one UPS must not de-energize the load. ECO mode reduces losses where the mains is stable, and the EPO input makes it possible to cut the supply in an emergency from a control panel. Cold start launches the UPS from the battery without mains, which is useful for starting equipment during an outage. The frequency converter mode is needed for consumers rated for a different mains frequency than the one available on site.

How to choose

The model is chosen by load power and installation place. Up to 3 kVA take IRIS+ in a tower case or IRISRT for a rack; at 6/10 kVA there are IRIS-RT and IRIS+L with N+X paralleling. If a light battery with a long service life is needed, look at IRIS-LFP with LiFePO4 for more than 2000 cycles. For a three-phase input and 10–30 kVA, IRIS+T/IRIS+TT is suitable.

Request a price and lead time

IRIS+ / IRISRT / IRIS-RT / IRIS+L online UPS 1–10 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the efficiency of the IRIS+ UPS at 1–3 kVA?

Above 92% in double-conversion mode. IRIS-RT at 6/10 kVA gives up to 94%.

Can IRIS-RT be connected in parallel?

Yes, 6/10 kVA models support N+X parallel redundancy. The number of units sets the required margin in case one of them fails.

What does cold start mean in IRIS UPS units?

It is starting the UPS from the battery when there is no mains. The function is available in the whole 1–10 kVA series.

How does IRISRT differ from IRIS+?

Both series are rated for 1–3 kVA, but IRISRT has a rack/tower version and can be mounted in a rack, while IRIS+ is made as a tower.

What is the output cos φ of the IRIS-RT series?

The output cos φ equals 1.0, so the power in kVA corresponds to the active power in kW.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.