ITA2 — online UPS 15–40 kVA for rack/tower
Country: USA · Model: ITA2
Compact double-conversion online UPS rated 15–40 kVA that mounts in a rack or stands on the floor. The 15 and 20 kVA models run at 208 V, the 30 and 40 kVA models at 400 V.
- Power
- 15/20 kVA (208 V), 30/40 kVA (400 V)
- Type
- online double conversion, parallel-capable
- Protection rating
- IP20
- Operating temperature
- 0–50 °C
Technical specifications
| Power | 15/20 kVA (208 V), 30/40 kVA (400 V) |
|---|---|
| Type | online double conversion, parallel-capable |
| Protection rating | IP20 |
| Operating temperature | 0–50 °C |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
It runs double conversion and supports several units in parallel, for more power or for redundancy. The IP20 enclosure is meant for indoor rooms with no dripping water or conductive dust. Operating temperature is 0–50 °C, giving headroom in server rooms and telecom cabinets without tight air conditioning. This UPS suits sites that need three-phase-class power in a rack format. The 400 V models connect to a standard three-phase board, while the 208 V versions are for networks and equipment built to that voltage. The rack format keeps the UPS next to the load, so cable runs from its output to the PDUs stay short.
How to choose
Voltage decides first, the 30 and 40 kVA versions for a 400 V three-phase network, the 15 and 20 kVA versions only where the site has a 208 V supply. A pair of units in parallel gives redundancy for one critical row of racks. If single-phase 20 kVA is enough, the alternatives are GXT5 at 16–20 kVA in 9U or the modular APS at 5–20 kVA with N+1. Above 40 kVA move to a floor-standing three-phase unit such as EXM2 at 100–250 kVA.
Request a price and lead time
ITA2 — online UPS 15–40 kVA for rack/tower. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the operating temperature range of ITA2?
From 0 to 50 °C, which suits rooms with weak cooling.
Which ITA2 ratings are made for 400 V?
The 30 and 40 kVA models are for 400 V, the 15 and 20 kVA models for 208 V.
Can ITA2 UPS units be paralleled?
Yes, the 15–40 kVA UPS is parallel-capable.
What IP rating does ITA2 have?
IP20, so it goes indoors into a clean server or electrical room.
Can ITA2 be installed in a rack?
Yes, the 15–40 kVA UPS mounts in a rack or stands on the floor as a tower.