OP — industrial online UPS 1–10 kVA
Country: France · Model: OP
The OP series consists of double-conversion online UPS units rated 1000–3000 VA and 5000–10000 VA for industrial automation. They are installed in control cabinets, communication rooms and telecom nodes, where the power must stay clean even during mains transients.
- Power
- 1000–3000 VA and 5000–10000 VA
- Classification
- VFI-SS-112 per EN 50091-3
- Output THD
- < 3 %
- Battery
- three-stage ABM charging
Technical specifications
| Power | 1000–3000 VA and 5000–10000 VA |
|---|---|
| Classification | VFI-SS-112 per EN 50091-3 |
| Output THD | < 3 % |
| Battery | three-stage ABM charging |
| Interfaces | RS232, USB, SNMP slot, EPO |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The inverter runs all the time, so the load does not notice the transfer to battery, and the output harmonic distortion stays below 3 %. According to EN 50091-3 the series is class VFI-SS-112, which means the output voltage does not depend on mains voltage and frequency fluctuations. The battery is managed by the ABM system with three-stage charging, which does not keep the cells on float voltage all the time and so slows their aging. For integration into process control systems there are RS232 and USB ports, a slot for an SNMP card for network monitoring and an EPO input for emergency shutdown from a panel. The lower range is meant for individual controllers and switches, the upper one for cabinets with several consumers.
How to choose
The model is chosen by the total load power, with a margin for power supply inrush currents and for cabinet expansion. If you need a LiFePO4 lithium battery with a life of more than 2000 cycles, look at IRIS-LFP of the same 1–10 kVA range. For a three-phase input and a 10–30 kVA load, move to IRIS+TT, where up to 4 UPS units run in parallel with a shared battery.
Request a price and lead time
OP — industrial online UPS 1–10 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What class is the OP UPS under EN 50091-3?
The series is class VFI-SS-112, that is, a double-conversion online UPS whose output does not depend on mains voltage and frequency.
What is the output voltage distortion of the OP UPS?
Output THD is below 3 %, so it can power PLCs, sensors and telecom equipment with sensitive power supplies.
How does the OP UPS charge the batteries?
The ABM system with three-stage charging is used. It does not keep the battery on constant float charge, which reduces wear.
Can the OP UPS be monitored over the network?
Yes, the case has an SNMP slot for a network card, as well as RS232 and USB ports and an EPO input for remote emergency shutdown.
What power range does the OP series cover?
Two model groups, 1000–3000 VA and 5000–10000 VA, which together cover the 1–10 kVA range.