Sentinel Tower — online UPS 5–10 kVA
Country: Italy · Model: Sentinel Tower
Sentinel Tower, a floor-standing online UPS on casters, is rated 5–10 kVA/kW at PF = 1. It feeds security systems, telecom and IT equipment, with the output on a terminal block and two IEC sockets.
- Power
- 5–10 kVA/kW (PF = 1)
- Input/output
- 1:1 (5–6 kVA); 1:1 or 3:1 (8–10 kVA)
- Topology
- online, VFI-SS-111, three-level inverter
- Efficiency
- up to 95 % (online), 98 % (ECO)
Technical specifications
| Power | 5–10 kVA/kW (PF = 1) |
|---|---|
| Input/output | 1:1 (5–6 kVA); 1:1 or 3:1 (8–10 kVA) |
| Topology | online, VFI-SS-111, three-level inverter |
| Efficiency | up to 95 % (online), 98 % (ECO) |
| Overload | 110 % — continuous, 130 % — 1 h, 150 % — 10 min |
| Parallel operation | up to 3 UPS |
| Batteries | VRLA AGM; ER versions without internal batteries, 6 A charger |
| Dimensions | 250×698×500 mm |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The 5–6 kVA models run 1:1, while the 8–10 kVA models accept single-phase or three-phase input (1:1 or 3:1), handy when the panel only has a three-phase feed. A three-level inverter and VFI-SS-111 topology give up to 95 % efficiency online and 98 % in ECO. Besides ON LINE and ECO there are SMART ACTIVE, STANDBY OFF and a 50/60 Hz frequency converter mode. The unit carries 110 % overload continuously, 130 % for 1 h and 150 % for 10 min, so pump and compressor starting currents pass without a transfer to bypass. Up to 3 UPS run in parallel. Internal batteries are VRLA AGM, and ER versions come without them and with a 6 A charger for external battery cabinets. The 250×698×500 mm housing passes a standard door and rolls to its place.
How to choose
Size the unit for total load with margin for starting currents. If the panel only offers three phases, you need the 8 or 10 kVA model with 3:1 input. For long runtime choose an ER version with an external battery cabinet. On ships and offshore platforms, the Sentinel Dual Marine at 6 and 10 kVA/kW with DNV type approval takes this series' place. For loads from 10 kVA with three-phase output, the Master MPS at 10–200 kVA fits, and emergency lighting to EN 50171 uses the CSS Sentinel Tower version at 3–5 kVA.
Request a price and lead time
Sentinel Tower — online UPS 5–10 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What overload can the Sentinel Tower carry?
110 % continuously, 130 % for 1 h and 150 % for 10 min.
Can the Sentinel Tower work as a frequency converter?
Yes, the UPS has a 50/60 Hz frequency converter mode.
What are the Sentinel Tower dimensions?
250×698×500 mm, and the housing stands on casters.
Can the Sentinel Tower connect to a three-phase supply?
Yes, the 8–10 kVA models run 3:1. The 5–6 kVA models are single-phase only, 1:1.
How many Sentinel Tower units can be paralleled?
Up to 3 units, for redundancy or more power.