SLC TWIN PRO3 / PRO3 MULTI — online UPS with IoT 4–20 kVA, PF=1
Country: Spain · Model: SLC TWIN PRO3 / PRO3 MULTI
The fourth generation of SLC TWIN online UPS with an output cos φ of 1.0 and a power of 4–20 kVA. Built-in IoT connectivity sends the unit status to the Nimbus cloud. They are intended for production shops, laboratories and server rooms with remote supervision.
- Power
- 4, 5, 6, 8, 10 kVA (B1 — 6 and 10 kVA with extended backup time); MULTI — 10, 15, 20 kVA
- Output cos φ
- 1.0
- MULTI configuration
- 3:3, 3:1, 1:1 by jumpers, two separate inputs
- Connectivity
- IoT, Nimbus cloud
Technical specifications
| Power | 4, 5, 6, 8, 10 kVA (B1 — 6 and 10 kVA with extended backup time); MULTI — 10, 15, 20 kVA |
|---|---|
| Output cos φ | 1.0 |
| MULTI configuration | 3:3, 3:1, 1:1 by jumpers, two separate inputs |
| Connectivity | IoT, Nimbus cloud |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The single-phase PRO3 range includes models of 4, 5, 6, 8 and 10 kVA. The B1 versions of 6 and 10 kVA have an extended backup time and hold the load longer from the batteries. A unity power factor means that 10 kVA on the nameplate corresponds to 10 kW at the output without recalculation. The PRO3 MULTI of 10, 15 and 20 kVA is switched by jumpers to the 3:3, 3:1 or 1:1 schemes and has two separate inputs. Therefore, the same unit suits both a three-phase and a single-phase network, and the scheme can be changed directly on site. The Nimbus cloud platform collects data on UPS operation, so the service team sees a fault without visiting the site.
How to choose
For a single-phase load up to 10 kVA the basic PRO3 is enough, and if longer battery operation is needed, take the B1 of 6 or 10 kVA. When the site network is three-phase or the load reaches 15–20 kVA, look at the MULTI. If cloud monitoring is not needed, the previous generation SLC TWIN PRO2 covers 0.7–20 kVA, but its smaller models have a cos φ of 0.9.
Request a price and lead time
SLC TWIN PRO3 / PRO3 MULTI — online UPS with IoT 4–20 kVA, PF=1. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which phase schemes does the SLC TWIN PRO3 MULTI support?
3:3, 3:1 and 1:1, switched by jumpers. The MULTI power is 10, 15 or 20 kVA.
What does the B1 mark mean in SLC TWIN PRO3?
It marks the versions of 6 and 10 kVA with an extended backup time on batteries.
How does Nimbus cloud monitoring work in SLC TWIN PRO3?
The UPS has built-in IoT connectivity and sends data to the Nimbus cloud platform, from where the unit status can be seen remotely.
What active power does the 10 kVA SLC TWIN PRO3 deliver?
The output cos φ is 1.0, so the 10 kVA model delivers 10 kW of active power.