SPS ADVANCE T / R2 / RT2 — line-interactive sine wave UPS 750–3000 VA
Country: Spain · Model: SPS ADVANCE T / R2 / RT2
Line-interactive UPS with a pure sine wave output in the range of 750–3000 VA, in three versions. The T tower, the R2 rack unit of 1U height and the universal RT2 of 2U cover server cabinets, switching rooms and computer rooms.
- Power
- T: 850–3000 VA (tower); R2: 750–1500 VA (1U); RT2: 800–3000 VA (2U rack/tower)
- Output
- pure sine wave; RT2 — cos φ 0.9
- Regulation
- AVR Buck/Boost
- Interfaces
- USB HID, RS-232; RT2 — slot for SNMP/Modbus/dry contacts
Technical specifications
| Power | T: 850–3000 VA (tower); R2: 750–1500 VA (1U); RT2: 800–3000 VA (2U rack/tower) |
|---|---|
| Output | pure sine wave; RT2 — cos φ 0.9 |
| Regulation | AVR Buck/Boost |
| Interfaces | USB HID, RS-232; RT2 — slot for SNMP/Modbus/dry contacts |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The sine wave output makes these UPS units suitable for server power supplies and equipment with sensitive switching power supplies, for which an approximated sine wave does not fit. The tower version T covers 850–3000 VA and is placed on the floor or a desk. The R2 takes only 1U in a rack and has a range of 750–1500 VA. The RT2 of 800–3000 VA is mounted in a 2U rack or placed vertically on stands, and its output cos φ is 0.9. AVR Buck/Boost regulation corrects the mains voltage without discharging the battery. For communication with a server there are USB HID and RS-232, through which software shuts down the OS correctly during a long outage. The RT2 additionally has a slot for an SNMP, Modbus or dry contact card, and the UPS is brought into the building monitoring system.
How to choose
First decide on the mounting method, because the version depends on it. For a rack with little space the R2 is suitable, but its limit is 1500 VA. If power up to 3000 VA in a rack or remote supervision through SNMP is needed, take the RT2. For office PCs without requirements for the voltage shape, SPS SOHO+ of 750–2250 VA is enough, and for loads that need double conversion there is the online SLC TWIN PRO2 of 0.7–20 kVA.
Request a price and lead time
SPS ADVANCE T / R2 / RT2 — line-interactive sine wave UPS 750–3000 VA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the difference between SPS ADVANCE T, R2 and RT2?
T is a tower of 850–3000 VA, R2 is a 1U rack unit of 750–1500 VA, RT2 is a universal 2U unit of 800–3000 VA with a slot for a communication card.
Does SPS ADVANCE give a pure sine wave?
Yes, all three versions have a sine wave output. The RT2 has an output power factor cos φ of 0.9.
How to connect the SPS ADVANCE RT2 to SNMP monitoring?
The RT2 has an expansion slot for an SNMP, Modbus or dry contact card. The T and R2 versions have USB HID and RS-232.
How much rack space does the SPS ADVANCE R2 take?
The R2 version is 1U high and has a power of 750–1500 VA. The RT2 takes 2U.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.