Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

Maxima 3PH A2R — three-phase online UPS 100–200 kVA

A three-phase online UPS rated 100–200 kVA with an output cos φ of 0.9 for data centers and continuous industrial processes. It is installed in a server room or electrical room as the central source of guaranteed power.

Power
100–200 kVA
Output cos φ
0.9
Efficiency
up to 94 % (inverter)
Parallel operation
up to 4 UPS units

Technical specifications

Power100–200 kVA
Output cos φ0.9
Efficiencyup to 94 % (inverter)
Parallel operationup to 4 UPS units
Batteryadjustable configuration, intelligent management

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The online topology powers the load all the time through the inverter, so the transfer to battery takes place without a break and without transients at the output. Active power is calculated as 0.9 of the kVA rating, which must be taken into account when distributing the load between phases. Inverter efficiency reaches 94 %, and the heat release and the air conditioning capacity of the room depend on it. Up to 4 UPS units are connected in parallel to increase power or for redundancy, when one unit backs up the others. The battery configuration is adjusted to the required runtime, and intelligent charge management preserves the life of the units. The case is floor-standing, cabinet type.

How to choose

The size is chosen by the active load, taking into account cos φ of 0.9 and a margin for site growth. If 200 kVA is not enough, a parallel system of up to 4 UPS units extends the capacity without replacing the equipment. For a load of 30–80 kVA the more compact Maxima 3PH A3R with cos φ of 1.0 and efficiency of up to 96 % online is available, and for 10–20 kVA Maxima 3PH UR.

Request a price and lead time

Maxima 3PH A2R — three-phase online UPS 100–200 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What active power does the Maxima A2R UPS deliver?

The output cos φ is 0.9, so the active power is obtained by multiplying the 100–200 kVA rating by 0.9.

How many Maxima 3PH A2R UPS units can be connected in parallel?

Up to 4 UPS units on a common load, which gives added power or redundancy.

What is the efficiency of the A2R three-phase UPS?

Inverter efficiency reaches 94 %, and the rest of the energy leaves as heat, which the air conditioning system has to remove.

Can the number of batteries in Maxima A2R be changed?

Yes, the battery configuration is adjustable, and the intelligent management monitors the charge and the condition of the units.

Which sites is Maxima 3PH A2R of 200 kVA intended for?

For data centers and industrial processes, where a power stop means loss of data or defective products.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.