SLC X-PERT — three-phase online UPS 80–400 kVA

A three-phase VFI double conversion online UPS of 80–400 kVA with high power density. It is designed for important sites where the machine room area and the total cost of ownership over the whole service life matter.

Power
80–400 kVA
Topology
online, double conversion (VFI)
Service
full front access (from 200 kVA)
Battery
common battery option

Technical specifications

Power80–400 kVA
Topologyonline, double conversion (VFI)
Servicefull front access (from 200 kVA)
Batterycommon battery option

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The VFI class means that the output voltage is formed by the inverter all the time and does not depend on fluctuations of the mains voltage and frequency. High power density makes it possible to place a UPS of several hundred kVA in a smaller area, which matters for data centers and industrial electrical rooms. Models from 200 kVA have full front access, so the cabinet is placed close to a wall or neighboring cabinets, and service work is done from the front. The common battery option lets several UPS work from one battery bank, and a parallel system needs fewer batteries and less space for them. The total cost of ownership consists of purchase costs, energy losses and maintenance, and the series is designed precisely to reduce it.

How to choose

The rating is chosen by the calculated load with a reserve for the growth of the site and by the redundancy scheme. Full front access is declared for models from 200 kVA, so for smaller sizes a service passage should be provided. If a parallel system is planned, include the common battery option at once. For a load above 400 kVA the manufacturer has the X-TRA series, and for small electrical rooms the three-phase CUBE3+.

Request a price and lead time

SLC X-PERT — three-phase online UPS 80–400 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

In what power range is the SLC X-PERT made?

From 80 to 400 kVA, all models are three-phase with VFI double conversion.

Is access to the back wall of the SLC X-PERT needed?

Models from 200 kVA have full front access, so maintenance is done from the front and the cabinet can be placed by a wall.

What does the common battery option in X-PERT give?

Several UPS in a parallel system work from one battery bank. This reduces the area and the number of battery cabinets.

For which sites is the SLC X-PERT intended?

For important sites of 80–400 kVA where high power density and a low total cost of ownership are needed, for example data centers and industrial enterprises.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.