Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

Keor HP — three-phase transformer-based UPS, 60–800 kVA

A three-phase online UPS for 60–800 kVA with an inverter isolation transformer, built for industry and infrastructure. Up to 6 units run in parallel in an N+X scheme, so one system can cover a large production line or a substation's auxiliary supply.

Power
60–800 kVA
Topology
online, IGBT rectifier and inverter, DSP
Output transformer
inverter isolation transformer
Parallel operation
up to 6 UPS units (N+X)

Technical specifications

Power60–800 kVA
Topologyonline, IGBT rectifier and inverter, DSP
Output transformerinverter isolation transformer
Parallel operationup to 6 UPS units (N+X)
Optioncentralized bypass for parallel systems
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Keor HP is a high-power, transformer-based three-phase machine. The rectifier and inverter use IGBTs under digital DSP control. The output transformer isolates the load from the inverter galvanically, a fresh neutral is formed on the output, and DC offset and switching noise from the power electronics never reach the loads. The transformer also copes better with motor inrush and phase imbalance, both common in plants. Parallel systems can take an optional centralized bypass, one for the whole group in place of a bypass in each unit. A transformer cabinet weighs more than a transformerless one, so check floor loading and door openings before delivery.

How to choose

Take the transformer model when you need galvanic isolation, a separate neutral for the load or tolerance of heavy motor starts. If isolation is not needed and efficiency comes first, consider the transformerless Keor XPE at up to 2.1 MVA with up to 96.4 % efficiency in VFI mode. Sites in the multi-MVA class fit UPSaver with 333 kVA modules and up to 2.67 MVA in one block.

Request a price and lead time

Keor HP — three-phase transformer-based UPS, 60–800 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many Keor HP units can run in parallel?

Up to 6 units in an N+X scheme, for capacity or redundancy.

Why does Keor HP have an isolation transformer?

The inverter transformer galvanically isolates the load from the UPS power electronics.

Does Keor HP offer a centralized bypass?

Yes, as an option for parallel systems, with one bypass serving the whole UPS group.

What power range does Keor HP cover?

60–800 kVA per unit, with more available by paralleling up to 6 units.

Is Keor HP suitable for motor loads?

Yes, the output transformer handles motor inrush and phase imbalance better than a transformerless design.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.