Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

Master HP / Master HE — three-phase transformer-based UPS 100–800 kVA

The Master HP and Master HE transformer-based online UPS units cover 100–800 kVA and target data centers and industrial loads. The IGBT rectifier barely affects the source (THDi <3 %), and the output transformer isolates the load from the batteries.

Power
Master HP — 100–600 kVA (90–540 kW); Master HE — 100–800 kVA/kW (PF = 1); Master HP UL — 65–500 kVA (480 V, 60 Hz, UL/CSA)
Topology
online, VFI-SS-111, IGBT rectifier, output isolation transformer
Efficiency
Master HP — up to 94.5 %, Master HE — up to 95.5 % (online); up to 99.4 % in STANDBY ON mode
Input
380/400/415 V, THDi <3 %, PF >0.99

Technical specifications

PowerMaster HP — 100–600 kVA (90–540 kW); Master HE — 100–800 kVA/kW (PF = 1); Master HP UL — 65–500 kVA (480 V, 60 Hz, UL/CSA)
Topologyonline, VFI-SS-111, IGBT rectifier, output isolation transformer
EfficiencyMaster HP — up to 94.5 %, Master HE — up to 95.5 % (online); up to 99.4 % in STANDBY ON mode
Input380/400/415 V, THDi <3 %, PF >0.99
Overload110 % — 60 min, 125 % — 10 min, 150 % — 1 min
BatteriesVRLA AGM/GEL, NiCd, Li-ion, supercapacitors, flywheels
Dimensions800×850×1900 … 2100×1000×1900 mm (100–600 kVA), IP20
Centralized bypassMaster Static Bypass MSB 800–3000 kVA for parallel systems
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Master HP comes in 100–600 kVA (90–540 kW) with up to 94.5 % efficiency, Master HE in 100–800 kVA/kW at PF 1 with up to 95.5 % in online mode. In STANDBY ON mode efficiency reaches 99.4 %. For 480 V, 60 Hz grids there is the Master HP UL at 65–500 kVA with UL/CSA certification. Master HE handles peak shaving and Smart Grid operation. The input takes 380/400/415 V at PF >0.99, so a diesel generator can be sized close to the UPS rating. The UPS carries 110 % overload for 60 min, 125 % for 10 min and 150 % for 1 min. Dimensions run from 800×850×1900 to 2100×1000×1900 mm for 100–600 kVA, and IP20 calls for a clean, dry room. It accepts VRLA AGM/GEL, NiCd and Li-ion batteries, supercapacitors and flywheels. Large parallel systems use the centralized MSB static bypass rated 800–3000 kVA.

How to choose

The load power factor decides between the series, and at PF 1 above 600 kVA only Master HE remains. The transformer design is needed where galvanic isolation matters. Without that need, and with up to 97 % online efficiency in view, consider the transformerless NextEnergy NXE at 250–800 kVA/kW. Smaller loads go to Master MPS at 10–200 kVA.

Request a price and lead time

Master HP / Master HE — three-phase transformer-based UPS 100–800 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the efficiency of the Master HE UPS?

Up to 95.5 % in online mode and up to 99.4 % in STANDBY ON mode.

How long does the Master HP carry an overload?

It carries 110 % for 60 min, 125 % for 10 min and 150 % for 1 min.

What is the Master Static Bypass MSB?

A centralized static bypass rated 800–3000 kVA for large parallel Master systems.

Can Master HP use lithium batteries?

Yes, besides VRLA AGM/GEL and NiCd it works with Li-ion, supercapacitors and flywheels.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.