The compact UltraCharge 80 fast DC charging station is supplied at 60 kW, and one 20 kW power module raises it to 80 kW. Two DC outputs and a cabinet depth of 300 mm let it stand on a narrow island between parking spaces, where a large cabinet would not fit.
- Power
- 60 kW, expandable to 80 kW (20 kW module)
- Outputs
- 2 DC cables 5 m (peak 250 A, rated 150 A), optionally 7 m
- Output voltage
- 150–1000 V
- Efficiency
- ≥ 96 %
Technical specifications
| Power | 60 kW, expandable to 80 kW (20 kW module) |
|---|---|
| Outputs | 2 DC cables 5 m (peak 250 A, rated 150 A), optionally 7 m |
| Output voltage | 150–1000 V |
| Efficiency | ≥ 96 % |
| Communication | 4G / Wi-Fi / Ethernet, OCPP 1.6, 10.1″ screen |
| Protection rating | IP54 / IK10 |
| Dimensions | 850 × 1700 × 300 mm |
| Weight | < 125 kg |
| Standards | EN 61851, IEC 62196, DIN 70121, ISO 15118-2, PAS 1899:2022 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The standard 60 kW suits a start with limited connection capacity, and the 20 kW module is added later when the grid is reinforced. The station shares power dynamically between two cars, so the second car starts charging without waiting for the first to finish. Each cable of 5 m (7 m optional) carries 150 A continuously and up to 250 A at peak, and the output voltage is adjustable within 150–1000 V. The efficiency is not lower than 96 %, so losses in the station itself do not exceed a few percent of the delivered energy. For communication there are 4G, Wi-Fi and Ethernet, the station is compatible with any OCPP platform using OCPP 1.6, and the driver controls the session from the 10.1″ screen. The 850 × 1700 × 300 mm cabinet weighing up to 125 kg is built to IP54 with IK10 impact resistance for outdoor use. The list of standards covers EN 61851, IEC 62196, DIN 70121, ISO 15118-2 and PAS 1899:2022.
How to choose
The choice comes down to whether 60 kW is enough at the start or whether to take the 20 kW module at once and have 80 kW. For a fleet depot, highway or port with heavy traffic, the UltraCharge 400 with 200–400 kW and a cable current of up to 500 A is more suitable. If cars stay for hours, DC charging is not needed and AC posts Quantum or BasicCharge with 7.4 or 22 kW are enough.
Request a price and lead time
UltraCharge 80 DC charging station 60–80 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What power does the UltraCharge 80 have and can it be increased?
60 kW as supplied. After a 20 kW power module is installed, the station delivers 80 kW, and the cabinet and installation site stay the same.
What current does the cable of the UltraCharge 80 DC station carry?
The rated current of each of the two DC cables is 150 A and the peak value is 250 A. The standard cable length is 5 m, or 7 m to order.
How much space does the UltraCharge 80 take?
The station measures 850 × 1700 × 300 mm and weighs less than 125 kg. The small cabinet depth suits tight car parks next to buildings.
Which management systems does the UltraCharge 80 work with?
With any OCPP platform using the OCPP 1.6 protocol. The connection to the server runs over 4G, Wi-Fi or Ethernet.
Can the UltraCharge 80 be installed outdoors?
Yes, the cabinet has protection rating IP54 and impact resistance IK10, so the station is installed in open car parks.