ENECTOR AC 3.7/11 and 7.4 (G1) EV charging station

The first-generation ENECTOR AC home charging station comes in 3.7/11 kW and 7.4 kW versions with a permanently attached 7.5 m Type 2 cable. Paired with PLENTICORE inverters it charges the car from surplus solar output.

Power
3.7/11 kW (3 phases, 16 A), 7.4 kW (1 phase, 32 A)
PV charging
starts at 1.4 kW surplus
Temperature
−25…+40 °C (up to +50 °C with derating)

Technical specifications

Power3.7/11 kW (3 phases, 16 A), 7.4 kW (1 phase, 32 A)
PV chargingstarts at 1.4 kW surplus
Temperature−25…+40 °C (up to +50 °C with derating)
More from the manufacturer’s documentation
Grid connection3N~ 400 V or 1N~ 230 V (3.7/11) / 1N~ 230 V (7.4)
Rated frequency50 Hz
Grid typeTN/TT
Input protectionMCB 20 (3.7/11) / MCB 40 (7.4), external RCD type A
DC residual current detectionintegrated (RDC-MD > 6 mA)
Charging cableType 2, 7.5 m, permanently attached
Standby consumption< 1 W
Rated insulation voltage500 V
Rated impulse withstand voltage4 kV
Protection ratingIP54 (housing); plug IP44 (3.7/11) / IP54 (7.4)
Impact resistanceIK10
Protection classI
Dimensions (H × W × D)400 × 260 × 160 mm
Weight4.7 kg
Max. installation altitude2,000 m
Relative humidityup to 95 % (non-condensing)
CommunicationModbus RTU for energy meter (e.g. KSEM)
Charging modesPower, Solar Pure, Solar Plus, Lock (via KSEM)
Mountingwall-mounted, cable entry top / bottom / rear
Warranty5 years (Smart Warranty)
StandardsCE, IEC 61851-1 (mode 3), DIN IEC/TS 61439-7
Customs codes (for reference)
HS code8537.10
UKTZED code (Ukraine)8537109890
CN code (EU)85371098

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The 3.7/11 kW version connects to 3 phases at 16 A, and the 7.4 kW version runs from 1 phase at 32 A. PV charging starts once surplus generation reaches 1.4 kW. Power, Solar Pure, Solar Plus and Lock modes are set through the KSEM, which feeds the charger data over Modbus RTU. The station is rated for −25 to +40 °C. When it heats up to +50 °C it keeps running at reduced power. Upstream it takes an MCB 20 for the 3.7/11 or an MCB 40 for the 7.4 plus an external type A RCD, while DC leakage above 6 mA is detected internally. The IP54, IK10 housing weighs 4.7 kg, and the plug is IP44 on the 3.7/11 and IP54 on the 7.4. Charging complies with IEC 61851-1 (mode 3).

How to choose

Choose the version by the supply, the 3.7/11 for a three-phase 3N~ 400 V service and the 7.4 for a single-phase 1N~ 230 V service with 32 A to spare. The newer ENECTOR G2 up to 11 kW speaks OCPP 1.6j and ISO 15118-20 and adds Wi-Fi and RFID, so it is the one for a charge management system or card access. Solar charging needs an inverter such as the PLENTICORE G3 at 4–20 kW.

Request a price and lead time

ENECTOR AC 3.7/11 and 7.4 (G1) EV charging station. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

At what surplus does ENECTOR AC PV charging start?

Charging starts at a 1.4 kW surplus, with power flow data coming from the KSEM meter.

How much current does the ENECTOR AC 7.4 draw?

32 A on a single phase at 7.4 kW, protected by an MCB 40.

What temperature range does the ENECTOR AC handle?

From −25 to +40 °C, and up to +50 °C with derating.

Can the ENECTOR AC be mounted outdoors?

The IP54, IK10 housing is made for outdoor wall mounting, and the plug on the 3.7/11 version is IP44.

How does the ENECTOR AC differ from the ENECTOR G2?

The G2 has OCPP 1.6j, ISO 15118-20, Wi-Fi and RFID, while the ENECTOR AC only talks to the meter over Modbus RTU.

Similar products

EV charging stations

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.