ENECTOR G2 / G2 MID EV charging station, 3.7/11 kW
Country: Germany · Model: ENECTOR G2
The ENECTOR G2 wall-mounted AC EV charger delivers up to 11 kW through a 7.5 m Type 2 cable and connects to a 3N~ 400 V or 1N~ 230 V supply. The G2 MID version adds a calibrated meter for sites where charging energy is billed separately.
- Power
- up to 11 kW
- Connection
- 3N~ 400 V or 1N~ 230 V
- Cable
- Type 2, 7.5 m
- Standards
- IEC 61851-1 (mode 3), ISO 15118-20, OCPP 1.6j
Technical specifications
| Power | up to 11 kW |
|---|---|
| Connection | 3N~ 400 V or 1N~ 230 V |
| Cable | Type 2, 7.5 m |
| Standards | IEC 61851-1 (mode 3), ISO 15118-20, OCPP 1.6j |
| Protection | DC residual current monitoring > 6 mA |
| Communication | LAN, Wi-Fi, RFID |
| More from the manufacturer’s documentation | |
| Max. current per phase | 16 A |
| Rated frequency | 50 Hz |
| Grid type | TN/TT |
| Input protection | MCB 20 A, external RCD type A |
| Standby consumption | 5 W |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Protection rating | IP54 |
| Impact resistance | IK10 |
| Protection class | I |
| Overvoltage category | III |
| Dimensions (H × W × D) | 412 × 242 × 180 mm |
| Weight | 4.9 kg (G2) / 5.3 kg (G2 MID) |
| Operating temperature | −30…+50 °C (with derating), 24 h average up to 35 °C |
| Max. installation altitude | 2,000 m |
| Relative humidity | up to 95 % (non-condensing) |
| Mounting | wall-mounted, cable entry top / bottom / rear |
| MID meter | integrated in G2 MID version |
| Charging modes | Solar Pure, Solar Plus, Power, Lock, Time; automatic phase switching |
| Load management | EEBUS, §14a EnWG ready |
| Protection functions | unbalanced load limitation, blackout protection, external shutdown |
| RFID cards included | 3 |
| Warranty | 5 years (Smart Warranty) |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504405500 |
| CN code (EU) | 85044060 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Current is limited to 16 A per phase, so the full 11 kW needs a three-phase supply, while one phase gives 3.7 kW. In Solar Pure and Solar Plus modes charging follows the output of the PV system, and the station switches between one and three phases on its own. Charging complies with IEC 61851-1 (mode 3), and ISO 15118-20 and OCPP 1.6j are supported. Built-in DC residual current monitoring trips above 6 mA, so an external type A RCD with a 20 A breaker is enough upstream. LAN and Wi-Fi handle communication, and users authorize with RFID. Over EEBUS the charger accepts load limiting commands, and blackout protection cuts the current when the house is already heavily loaded. The IP54, IK10 housing goes on a wall with the supply cable entering from the top, bottom or rear.
How to choose
The supply decides it, with 11 kW on 3N~ 400 V and 3.7 kW on 1N~ 230 V. The plain G2 suits a private house, and the G2 MID goes where charging must be billed from a calibrated meter. Solar charging needs an inverter on site, such as the PLENTICORE G3 hybrid at 4–20 kW, with a KEM meter at the grid connection reporting power flows to the charger.
Request a price and lead time
ENECTOR G2 / G2 MID EV charging station, 3.7/11 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How much power does the ENECTOR G2 deliver?
Up to 11 kW on a 3N~ 400 V supply and 3.7 kW on 1N~ 230 V.
Does the ENECTOR G2 support OCPP?
Yes, OCPP 1.6j along with ISO 15118-20, so the charger can join an external charge management system.
How long is the ENECTOR G2 cable?
The Type 2 cable is 7.5 m long.
Does the ENECTOR G2 need a type B RCD?
No, the charger monitors DC residual current above 6 mA itself, so a type A RCD and a 20 A breaker go upstream.
How does the ENECTOR G2 MID differ from the G2?
The MID version has an integrated calibrated meter and weighs 5.3 kg against 4.9 kg for the G2.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.