Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

EV CHARGING STATIONS

OM X-Series liquid-cooled power cabinet, 800–1600 kW

The liquid-cooled X-Series power cabinet delivers up to 800 kW in a single X800 enclosure and up to 1600 kW with two X1600 cabinets. It supplies the chargers of the modular OM system at busy sites, from highway hubs to logistics terminals.

Power
X800 up to 800 kW (1 cabinet), X1600 up to 1600 kW (2 cabinets)
Outputs
up to 12 per cabinet (X1600 up to 24), distribution step 66.5 kW
Output voltage
200–950 V DC, current up to 2160 A
Efficiency
up to 98% (SiC, liquid cooling)

Technical specifications

PowerX800 up to 800 kW (1 cabinet), X1600 up to 1600 kW (2 cabinets)
Outputsup to 12 per cabinet (X1600 up to 24), distribution step 66.5 kW
Output voltage200–950 V DC, current up to 2160 A
Efficiencyup to 98% (SiC, liquid cooling)
Input400 V AC (CE) / 480 V AC (NA)
DC bus1000 A, BESS connection
Protection ratingIP65 / NEMA 4X, IK10
Dimensions, weight2150 × 1830 × 1020 mm; 2500 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The silicon carbide (SiC) power electronics with liquid cooling work at up to 98% efficiency. One cabinet serves up to 12 outputs, and the X1600 up to 24, with power redistributed between them in 66.5 kW steps. The output voltage of 200–950 V DC and total current of up to 2160 A cover both passenger and heavy-duty vehicle platforms. The open 1000 A DC bus allows a battery energy storage system (BESS) to be connected directly and the site capacity to be extended to multi-megawatt level, relieving the grid connection at peak hours. The cabinet is powered from 400 V AC in the European version or 480 V AC in the North American one. The IP65 / NEMA 4X enclosure with IK10 impact resistance is designed for outdoor use, and the weight of 2500 kg with dimensions of 2150 × 1830 × 1020 mm requires a concrete base.

How to choose

The choice between X800 and X1600 depends on the number of outputs and the total power of the hub. If there are fewer vehicles on the site and air cooling is sufficient, it is more practical to choose the M-Series at 200–1200 kW with a distribution step of 50 kW. For megawatt charging of trucks, an OM Ultra charger rated at 1.2 MW and 1500 A is connected to the X-Series, while a bus depot is usually covered by the HVC360.

Request a price and lead time

OM X-Series liquid-cooled power cabinet, 800–1600 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does the OM X-Series power cabinet have?

The X800 delivers up to 800 kW in one cabinet, the X1600 up to 1600 kW in two cabinets.

How many charging outputs can be connected to the X-Series?

Up to 12 per cabinet, and up to 24 in the X1600 configuration, with a power distribution step of 66.5 kW.

Can an energy storage system be connected to the OM X-Series?

Yes, the cabinet has an open 1000 A DC bus for direct BESS connection.

What is the efficiency of the X-Series cabinet?

Up to 98%; the power modules are built on SiC with liquid cooling.

What output voltage and current does the X-Series provide?

200–950 V DC with a total current of up to 2160 A.

Similar products

EV charging stations

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.