KSTAR Deep Cycle deep-discharge batteries, 2/12 V, 38–2000 Ah
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: Deep Cycle
Deep Cycle lead-acid batteries are built for cyclic duty, not for standby float service. The capacity is 38–2000 Ah and the cell voltage is 2 or 12 V. They are installed in solar plants with storage and in energy storage systems, where the battery gives up a noticeable share of its charge every day.
- Capacity
- 38–2000 Ah
- Voltage
- 2 and 12 V
- Service life
- 15 years (2 V), 10 years (12 V)
- Operating temperature
- −20…+50 °C
Technical specifications
| Capacity | 38–2000 Ah |
|---|---|
| Voltage | 2 and 12 V |
| Service life | 15 years (2 V), 10 years (12 V) |
| Operating temperature | −20…+50 °C |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Deep-discharge batteries are made for regular charge and discharge cycles, so they serve solar installations and storage systems, where the battery works daily rather than once a year as emergency backup. The range has two cell types. The 2 V versions have a stated service life of 15 years, the 12 V monoblocks 10 years. The 2 V cells are assembled into a series string of the required voltage, which for capacities up to 2000 Ah is more convenient than paralleling many monoblocks. The 12 V monoblocks are easier to mount in small installations. With a range of −20…+50 °C, the battery is better placed in a heated room or a climate-controlled cabinet than on an open site.
How to choose
Start with cell voltage and the capacity within 38–2000 Ah. For large capacities and long life take 2 V cells (15 years), for small systems the 12 V monoblocks (10 years). For constant float charging the GEL series is closer, with 12 V gel batteries, −40…+65 °C and up to 20 years. For lithium chemistry with a built-in BMS and over 3500 cycles, look at the LFP, 12.8 V.
Request a price and lead time
Deep Cycle deep-discharge batteries, 2/12 V, 38–2000 Ah, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What are the capacity and voltage of Deep Cycle batteries?
The capacity is 38–2000 Ah and the cell voltage is 2 or 12 V. The 2 V cells are connected in series to the required battery voltage.
What is the service life of Deep Cycle batteries?
15 years is stated for the 2 V cells and 10 years for the 12 V monoblocks.
Are these batteries suitable for solar plants and storage systems?
Yes, the series is made for cyclic operation in solar installations and storage systems. The operating temperature is −20…+50 °C, so choose an enclosed location.
How does Deep Cycle differ from GEL gel batteries?
The GEL is made for 12 V with a range of −40…+65 °C and a life of up to 20 years in float mode. Deep Cycle comes in two voltages, 2 and 12 V, but works in a narrower range of −20…+50 °C.
More from KSTAR
FM / FML / FMH / GFM / High RateFM / FML / FMH / GFM / High Rate VRLA lead-acid batteries, 2/6/12 V
GELGEL gel batteries, 12 V, 38–2000 Ah
LFP 12,8 VLFP lithium iron phosphate batteries, 12.8 V
BlueCore BIS60–260EIndoor battery system 60–261 kWh
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
UDUD three-phase online UPS 10–80 kVA
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVASimilar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.