KSTAR YDC3300 three-phase high-frequency online UPS 10–200 kVA
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: YDC3300
The YDC3300 is a three-phase online UPS at 10–40 and 50–200 kVA, transformerless, with a three-level inverter. It is built for data centers and withstands 100% unbalanced load.
- Power
- 10–40 kVA, 50–200 kVA; UL versions 10–20 and 25–100 kVA
- Phases
- 3:3
- Efficiency
- up to 95.8%
- Input voltage
- 138–485 V AC
Technical specifications
| Power | 10–40 kVA, 50–200 kVA; UL versions 10–20 and 25–100 kVA |
|---|---|
| Phases | 3:3 |
| Efficiency | up to 95.8% |
| Input voltage | 138–485 V AC |
| Power factor | input 0.99, output up to 1.0 |
| Parallel operation | up to 8 UPS units |
| Batteries | 30–50 pcs (UL version: 16–26) |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Efficiency reaches 95.8%, the input power factor is 0.99 and the output one up to 1.0, so nearly all the apparent power in kVA becomes active power in kW. The wide input voltage window of 138–485 V AC reduces the number of transfers to battery on an unstable grid. The 3:3 scheme means a three-phase input and a three-phase output. The UPS is compatible with generators, so it can be installed in systems with diesel or gas backup. The battery string consists of 30–50 blocks, and 16–26 in the UL version. Up to 8 UPS units are connected in parallel to add capacity or redundancy. The transformerless design reduces the weight and footprint of the cabinet compared with UPS units that have input and output transformers.
How to choose
First determine the load power. The base ranges are 10–40 and 50–200 kVA, and 10–20 and 25–100 kVA for the UL versions. If you need up to 80 kVA, there is the UD at 10–80 kVA. For a modular scheme with hot-swap modules, look at the HPM3300E at 10–150 kVA. The number of battery blocks in the string is agreed with the chosen version.
Request a price and lead time
YDC3300 three-phase high-frequency online UPS 10–200 kVA, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What power ratings does the YDC3300 come in?
The ranges are 10–40 and 50–200 kVA, and the UL versions are made for 10–20 and 25–100 kVA.
What are the efficiency and power factor of the YDC3300?
Efficiency is up to 95.8%, input power factor 0.99 and output power factor up to 1.0.
How many UPS units can be connected in parallel?
Up to 8 UPS units. A parallel connection gives spare capacity or redundancy in case one unit fails.
Does the YDC3300 withstand unbalanced load?
Yes, the UPS withstands 100% unbalanced load, so single-phase consumers on different phases do not limit it.
How many battery blocks does the YDC3300 need?
The standard version takes 30–50 blocks, the UL version 16–26.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
UDUD three-phase online UPS 10–80 kVA
HPM3300EHPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
HPM3300EHPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWEREPOWER industrial transformer-based UPS 10–800 kVA 3:3
EPOWER-HEPOWER-H IGBT transformer-based UPS 10–600 kVASimilar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.