KSTAR UCR online UPS 6–10 kVA 3:1 rack/tower

Supplied as an official KSTAR partner

The UCR online UPS is rated 6–10 kVA with a three-phase input and single-phase output (3:1), in a rack/tower case. Double conversion with DSP control isolates the load from the grid, and N+X parallel operation gives a reserve for critical IT equipment.

Power
6–10 kVA
Phases
3:1
Power factor
0.9
Design
rack/tower, rotating display

Technical specifications

Power6–10 kVA
Phases3:1
Power factor0.9
Designrack/tower, rotating display
RedundancyN+X parallel operation
FunctionsEPO

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The inverter continuously forms the output voltage here, so grid faults do not reach servers and switches. The case is placed as a tower or in a rack, and the display rotates to suit the chosen position. A power factor of 0.9 means the load in kW is 0.9 of the rating in kVA; this difference is taken into account when sizing a UPS for servers. For fault-tolerant setups, units are connected in parallel on the N+X principle, where X extra UPS units back up the N that are needed. The EPO input is meant for emergency shutdown, for example from a button at the entrance to the machine room.

How to choose

The choice is set by power within 6–10 kVA and the 3:1 phase configuration. If the supply is single-phase, there is the MEMOPOWER-III at 1–10 kVA with an input power factor of 0.99 and efficiency up to 94% in the 6–10 kVA RT version. For a three-phase 3:3 output, take the UD at 10–80 kVA or the YDC3300 at 10–200 kVA with efficiency up to 95.8%. When capacity has to grow in hot-swap modules, the HPM3300E at 10–150 kVA fits.

Request a price and lead time

UCR online UPS 6–10 kVA 3:1 rack/tower, KSTAR. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What does the 3:1 phase configuration of the UCR mean?

The 3:1 designation reads as a three-phase input and a single-phase output. The UPS is connected to a three-phase grid, while the load is fed from one phase.

What is the active power of the UCR in kW?

The power factor is 0.9, so active power equals 0.9 of the rating in kVA. The unit is rated 6–10 kVA.

Can several UCR units be connected in parallel?

Yes, parallel operation in an N+X scheme is provided. The number of units is not stated in the data and should be checked in the technical description.

What is the EPO function in the UCR for?

EPO is an emergency power-off input. With a single contact, for example from a button, the UPS is taken off the output circuit.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.