KSTAR UCR online UPS 6–10 kVA 3:1 rack/tower
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: UCR
The UCR online UPS is rated 6–10 kVA with a three-phase input and single-phase output (3:1), in a rack/tower case. Double conversion with DSP control isolates the load from the grid, and N+X parallel operation gives a reserve for critical IT equipment.
- Power
- 6–10 kVA
- Phases
- 3:1
- Power factor
- 0.9
- Design
- rack/tower, rotating display
Technical specifications
| Power | 6–10 kVA |
|---|---|
| Phases | 3:1 |
| Power factor | 0.9 |
| Design | rack/tower, rotating display |
| Redundancy | N+X parallel operation |
| Functions | EPO |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The inverter continuously forms the output voltage here, so grid faults do not reach servers and switches. The case is placed as a tower or in a rack, and the display rotates to suit the chosen position. A power factor of 0.9 means the load in kW is 0.9 of the rating in kVA; this difference is taken into account when sizing a UPS for servers. For fault-tolerant setups, units are connected in parallel on the N+X principle, where X extra UPS units back up the N that are needed. The EPO input is meant for emergency shutdown, for example from a button at the entrance to the machine room.
How to choose
The choice is set by power within 6–10 kVA and the 3:1 phase configuration. If the supply is single-phase, there is the MEMOPOWER-III at 1–10 kVA with an input power factor of 0.99 and efficiency up to 94% in the 6–10 kVA RT version. For a three-phase 3:3 output, take the UD at 10–80 kVA or the YDC3300 at 10–200 kVA with efficiency up to 95.8%. When capacity has to grow in hot-swap modules, the HPM3300E at 10–150 kVA fits.
Request a price and lead time
UCR online UPS 6–10 kVA 3:1 rack/tower, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What does the 3:1 phase configuration of the UCR mean?
The 3:1 designation reads as a three-phase input and a single-phase output. The UPS is connected to a three-phase grid, while the load is fed from one phase.
What is the active power of the UCR in kW?
The power factor is 0.9, so active power equals 0.9 of the rating in kVA. The unit is rated 6–10 kVA.
Can several UCR units be connected in parallel?
Yes, parallel operation in an N+X scheme is provided. The number of units is not stated in the data and should be checked in the technical description.
What is the EPO function in the UCR for?
EPO is an emergency power-off input. With a single contact, for example from a button, the UPS is taken off the output circuit.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UDUD three-phase online UPS 10–80 kVA
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVA
HPM3300EHPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
HPM3300EHPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWEREPOWER industrial transformer-based UPS 10–800 kVA 3:3
EPOWER-HEPOWER-H IGBT transformer-based UPS 10–600 kVASimilar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.