KSTAR UD three-phase online UPS 10–80 kVA
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: UD
A three-phase double-conversion online UPS rated 10–80 kVA with 3:3 phase configuration. It is meant for server rooms and industrial sites where the load cannot be left without power even for an instant.
- Power
- 10–80 kVA
- Phases
- 3:3
- Power factor
- 0.9
- Control
- DSP
Technical specifications
| Power | 10–80 kVA |
|---|---|
| Phases | 3:3 |
| Power factor | 0.9 |
| Control | DSP |
| Redundancy | N+X |
| Functions | ECO mode, adjustable charging current |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
A power factor of 0.9 means the active power in kW is nine tenths of the apparent power in kVA. Keep this in mind when comparing with models that have a factor of 1.0. In double-conversion mode the load is fed from the inverter all the time, so sags, voltage surges and grid noise do not reach it. A DSP processor runs the circuit, and a digital algorithm keeps the output stable. Units can be connected in an N+X scheme, either adding capacity or adding a standby unit in case one of them fails. An ECO mode is provided to save energy, and the battery charging current is adjustable, so it is set to match the capacity of the battery string and its permissible charging current.
How to choose
First calculate the load in kW rather than kVA, with a correction for the 0.9 factor. The UD covers 10–80 kVA. For smaller ratings there is the UCR at 6–10 kVA with 3:1 phases, for higher ratings and high efficiency the YDC3300 at 10–200 kVA with efficiency up to 95.8%, and for a modular architecture the HPM3300E at 10–150 kVA. If the supply is single-phase and up to 10 kVA, look at the MEMOPOWER-III.
Request a price and lead time
UD three-phase online UPS 10–80 kVA, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What are the rating and phase configuration of the UD?
The UD is made for 10–80 kVA with 3:3 phases, meaning a three-phase input and a three-phase output.
What is the active power of the UD?
The power factor is 0.9, so active power in kW is nine tenths of the rated power in kVA.
Can several UD units be combined?
Yes, N+X redundancy is provided and is used to add capacity or a reserve.
What is the ECO mode for?
It reduces losses while the grid is normal. The battery charging current is adjusted separately.
What does double conversion give in the UD?
The load is fed from the inverter all the time, so grid sags and surges do not reach it. A DSP processor handles the control.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVA
HPM3300EHPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
HPM3300EHPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWEREPOWER industrial transformer-based UPS 10–800 kVA 3:3
EPOWER-HEPOWER-H IGBT transformer-based UPS 10–600 kVASimilar products