PowerUPS 6000 Industrial — industrial UPS 6–200 kVA
Country: USA · Model: PowerUPS 6000 Industrial
Industrial UPS rated 6–200 kVA in single- and three-phase versions with a 0 ms transfer time. It works in harsh conditions in manufacturing, transport, logistics, cement plants and oil and gas, where the load includes motors, valves and control cabinets.
- Power
- 6–200 kVA, single- and three-phase
- Voltage
- 220 V (1-ph), 380/400/415 V (3-ph)
- Batteries
- VRLA, Ni-Cd, Li-ion
- Transfer time
- 0 ms
Technical specifications
| Power | 6–200 kVA, single- and three-phase |
|---|---|
| Voltage | 220 V (1-ph), 380/400/415 V (3-ph) |
| Batteries | VRLA, Ni-Cd, Li-ion |
| Transfer time | 0 ms |
| Inverter overload | 105–125% 10 min, 125–150% 1 min |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Ukrainian replacement/analogue
- Three-phase UPS Volter UPS DPH 20–120 kW (online, double conversion)
- Three-phase UPS Volter UPS-30KVA and UPS-40KVA (27 and 33 kW)
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Single-phase models run at 220 V and three-phase models at 380/400/415 V, so the unit feeds a single control panel or the board of a whole process line. The inverter carries 105–125% overload for 10 min and 125–150% for 1 min, enough for motor starts and the inrush of transformers and drives. The battery is matched to the site, with VRLA, nickel-cadmium Ni-Cd or Li-ion options. Ni-Cd is the usual pick for hot, unheated substations and outdoor shelters, where lead-acid ages fast. On industrial sites the UPS backs up process control, emergency shutdown and safety systems until the process reaches a safe state. With 0 ms transfer, PLCs and relays do not notice the feeder trip.
How to choose
First fix the phase count, a single-phase 220 V unit for one panel or a three-phase 380/400/415 V unit for a switchboard. Then check the rating against the heaviest motor start within the overload window, since steady-state load rarely decides. Battery chemistry follows room temperature and required life, Ni-Cd for unheated rooms, VRLA or Li-ion for conditioned ones. A clean IT room of 100–250 kVA is simpler on a EXM2 monoblock, and above 300 kW the step is EXL S1.
Request a price and lead time
PowerUPS 6000 Industrial — industrial UPS 6–200 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What overload can the PowerUPS 6000 Industrial inverter handle?
105–125% for 10 min and 125–150% for 1 min, which covers motor starts without going to bypass.
What batteries can the PowerUPS 6000 industrial UPS use?
VRLA, Ni-Cd or Li-ion across the 6–200 kVA range.
What is the transfer time of PowerUPS 6000 Industrial?
Transfer time is 0 ms, so PLCs and relays do not drop out when the mains fail.
Is PowerUPS 6000 Industrial available in single-phase?
Yes, single-phase models run at 220 V and three-phase models at 380/400/415 V, within 6–200 kVA.
Why choose Ni-Cd batteries for an industrial UPS?
Nickel-cadmium cells tolerate heat and deep discharge better than lead-acid, so they go into unheated substations. PowerUPS 6000 Industrial accepts Ni-Cd alongside VRLA and Li-ion.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.