Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

EV CHARGING STATIONS

Hypercharger HYC400 monobloc 100–400 kW DC charging station

The HYC400 monobloc DC station of 100–400 kW charges two electric vehicles at the same time at 200 kW each. Such a station is installed at highway charging hubs, logistics terminals and truck and bus depots, where every minute of vehicle downtime has a cost.

Power
100–400 kW (1–4 power modules), 2 × 200 kW simultaneously
Current
up to 2 × 600 A
Output voltage
150–1000 V DC
Connectors
CCS2 up to 600 A, CHAdeMO up to 200 A; CCS1, NACS, GB/T on request

Technical specifications

Power100–400 kW (1–4 power modules), 2 × 200 kW simultaneously
Currentup to 2 × 600 A
Output voltage150–1000 V DC
ConnectorsCCS2 up to 600 A, CHAdeMO up to 200 A; CCS1, NACS, GB/T on request
Efficiencyup to 97.7 % at full load
Input400 V AC, up to 630 A
Protection ratingIP54, IK10
Dimensions, weight2185 × 732 × 663 mm; 560–890 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The modular Power-Stack architecture based on SiC makes it possible to start with 100 kW and bring the station up to 400 kW by adding power modules to the same cabinet. Each of the two outputs holds up to 600 A, so high power is also available to cars with a low-voltage battery, which are held back by the current limit on weaker stations. The 150–1000 V DC range covers passenger cars, buses and trucks. The basic connectors are CCS2 up to 600 A and CHAdeMO up to 200 A, and CCS1, NACS or GB/T are fitted on request. At full load the efficiency reaches 97.7 %. The supply is 400 V AC with a current of up to 630 A, so the full version needs a dedicated supply, and the cable and input breaker are sized for this current. The IP54 enclosure with IK10 rating is built for outdoor use and accidental impacts. The dimensions are 2185 × 732 × 663 mm and the weight is 560–890 kg depending on the number of modules. The station has the TÜV SÜD CB certificate DE3-D0044.

How to choose

The number of modules is chosen by traffic flow and grid reserve, since every 100 kW adds load on the transformer. If 100 kW per car is enough for two cars, the narrower HYC200 takes less space. The HYC400 Series 2 on SiC-Stack Gen 2 has the same 400 kW limit, but it is adjustable in steps of 50 kW and shows a peak efficiency of 98.2 %. When the site needs more than two charging points, the distributed HYC1000 system is more sensible: a 1000 kW power cabinet shares the power in steps of 62.5 kW among 8 outputs.

Request a price and lead time

Hypercharger HYC400 monobloc 100–400 kW DC charging station. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Can the power of the HYC400 be increased after installation?

Yes, the station is modular and can be expanded from 100 to 400 kW by adding power modules, four at most. It is better to size the supply and cable for 630 A from the start.

What current does the HYC400 draw from the grid?

In the full configuration up to 630 A at 400 V AC. Such a load usually requires its own transformer substation or a dedicated feeder.

How many kilowatts does each car get on the HYC400?

Two cars at the same time get 200 kW each, with up to 600 A at each output. When one car is connected, it has the power of all installed modules available.

What is the weight of the HYC400 and how is it installed?

The weight is 560–890 kg with dimensions of 2185 × 732 × 663 mm. The station is set in place with a loader crane on a foundation poured in advance.

Similar products

EV charging stations

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.