KSTAR EPOWER industrial transformer-based UPS 10–800 kVA 3:3
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: EPOWER
The EPOWER is a three-phase online UPS with transformers at the input and output, rated from 10 to 800 kVA. The model is meant for industrial and control systems in harsh conditions; more than 30 000 units have been sold. The output power factor is 0.9.
- Power
- 10–80 kVA and 100–800 kVA
- Phases
- 3:3
- Power factor
- output 0.9
- Topology
- online, with input and output isolation transformers
Technical specifications
| Power | 10–80 kVA and 100–800 kVA |
|---|---|
| Phases | 3:3 |
| Power factor | output 0.9 |
| Topology | online, with input and output isolation transformers |
| Overload | 110% / 125% / 150% for 60 / 10 / 1 min (10–80 kVA) |
| Parallel operation | up to 6 UPS units |
| Standard | IEC EN 62040-3 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The double-conversion scheme with input and output isolation transformers galvanically separates the load from the grid. For industrial sites with noise and phase imbalance this matters a lot. The range splits into two groups, 10–80 kVA and 100–800 kVA, both with a three-phase input and output (3:3). On the 10–80 kVA models an overload of 110% lasts 60 min, 125% lasts 10 min, and 150% lasts 1 min. Up to six UPS units can be connected in parallel to add capacity or redundancy. The design complies with IEC EN 62040-3. It is installed at substations, process lines and control panels, where a load failure costs more than the UPS itself.
How to choose
Power is chosen by the active load in kW, bearing in mind the 0.9 factor at the output. If you need headroom for inrush currents, look at the overload curve. For critical consumers install several UPS units in parallel, up to 6. When transformers are not needed and size and efficiency matter, compare with the UD at 10–80 kVA or the high-frequency YDC3300 at 10–200 kVA.
Request a price and lead time
EPOWER industrial transformer-based UPS 10–800 kVA 3:3, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What power range does the EPOWER cover?
The range covers 10–80 kVA and 100–800 kVA, with a three-phase input and output (3:3). The output power factor is 0.9.
How many UPS units can be connected in parallel?
Up to 6 units. This gives redundancy or a larger total capacity.
What overload can the UPS withstand?
For the 10–80 kVA models it is 110% for 60 min, 125% for 10 min and 150% for 1 min.
Why does a UPS need isolation transformers?
They galvanically separate the load from the grid. This matters in industrial conditions with noise.
Which standard does this UPS comply with?
The design complies with IEC EN 62040-3. The series has more than 30 000 units sold.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
UDUD three-phase online UPS 10–80 kVA
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVA
HPM3300EHPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
HPM3300EHPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWER-HEPOWER-H IGBT transformer-based UPS 10–600 kVASimilar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.