KSTAR HPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: HPM3300E
The HPM3300E modular three-phase UPS covers 10–150 kVA, and a single power module is rated 100 kW in a 3U case. It is installed in server rooms and modular data centers where replacing a unit must not stop the load.
- Power
- 10–150 kVA; versions: 19-inch subrack, RT 10–50 kVA, 100 kW/3U module
- Efficiency
- 95.8–96%, up to 99% in HECO mode
- Power factor
- input 0.99, output 1.0
- Parallel operation
- up to 8 systems
Technical specifications
| Power | 10–150 kVA; versions: 19-inch subrack, RT 10–50 kVA, 100 kW/3U module |
|---|---|
| Efficiency | 95.8–96%, up to 99% in HECO mode |
| Power factor | input 0.99, output 1.0 |
| Parallel operation | up to 8 systems |
| Modules | power, bypass, monitoring: hot-swappable |
| Display | 7 or 10 inch touchscreen |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The system consists of power modules, a bypass module and a monitoring module, and each of the three types can be swapped hot. The versions differ in mounting. There is a subrack variant for a 19-inch rack, an RT version at 10–50 kVA, and the largest unit is the 100 kW module. Efficiency is 95.8–96%, and in HECO mode it reaches 99%, so less heat is released in the machine room. Input power factor is 0.99 and output is 1.0, so the kVA rating equals the active power in kW. Control and diagnostics are gathered on a 7 or 10 inch touchscreen. Lithium batteries are supported for backup storage, so the bank does not have to be built from lead-acid blocks.
How to choose
Power sets the number of power modules, while the subrack or RT version settles rack mounting. If hot swap is not needed and the load does not exceed 80 kVA, the monoblock UD at 10–80 kVA is enough. For non-modular models up to 200 kVA there is the YDC3300, which runs up to 8 UPS units in parallel. When capacity is added in stages and service must not stop the hall, take the HPM3300E, where up to 8 systems are connected in parallel.
Request a price and lead time
HPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the power range of the HPM3300E?
The system covers 10–150 kVA. RT versions are rated 10–50 kVA, and one power module is 100 kW in a 3U case.
Can UPS modules be replaced without switching off the load?
Yes, the power modules, bypass and monitoring module are hot-swap units. Service does not require stopping the hall.
What is the UPS efficiency in HECO mode?
In normal mode efficiency is 95.8–96%, and in HECO mode it reaches 99%.
How many HPM3300E systems can be connected in parallel?
Up to 8 systems. This gives capacity beyond the 150 kVA of a single system.
What power factor does this UPS have?
0.99 at the input and 1.0 at the output. So the rated kVA at the output equals the kW of active load.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
UDUD three-phase online UPS 10–80 kVA
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVA
HPM3300EHPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWEREPOWER industrial transformer-based UPS 10–800 kVA 3:3
EPOWER-HEPOWER-H IGBT transformer-based UPS 10–600 kVASimilar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.