KSTAR HPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules

Supplied as an official KSTAR partner

The HPM3300E modular three-phase UPS covers 10–150 kVA, and a single power module is rated 100 kW in a 3U case. It is installed in server rooms and modular data centers where replacing a unit must not stop the load.

Power
10–150 kVA; versions: 19-inch subrack, RT 10–50 kVA, 100 kW/3U module
Efficiency
95.8–96%, up to 99% in HECO mode
Power factor
input 0.99, output 1.0
Parallel operation
up to 8 systems

Technical specifications

Power10–150 kVA; versions: 19-inch subrack, RT 10–50 kVA, 100 kW/3U module
Efficiency95.8–96%, up to 99% in HECO mode
Power factorinput 0.99, output 1.0
Parallel operationup to 8 systems
Modulespower, bypass, monitoring: hot-swappable
Display7 or 10 inch touchscreen

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The system consists of power modules, a bypass module and a monitoring module, and each of the three types can be swapped hot. The versions differ in mounting. There is a subrack variant for a 19-inch rack, an RT version at 10–50 kVA, and the largest unit is the 100 kW module. Efficiency is 95.8–96%, and in HECO mode it reaches 99%, so less heat is released in the machine room. Input power factor is 0.99 and output is 1.0, so the kVA rating equals the active power in kW. Control and diagnostics are gathered on a 7 or 10 inch touchscreen. Lithium batteries are supported for backup storage, so the bank does not have to be built from lead-acid blocks.

How to choose

Power sets the number of power modules, while the subrack or RT version settles rack mounting. If hot swap is not needed and the load does not exceed 80 kVA, the monoblock UD at 10–80 kVA is enough. For non-modular models up to 200 kVA there is the YDC3300, which runs up to 8 UPS units in parallel. When capacity is added in stages and service must not stop the hall, take the HPM3300E, where up to 8 systems are connected in parallel.

Request a price and lead time

HPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules, KSTAR. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power range of the HPM3300E?

The system covers 10–150 kVA. RT versions are rated 10–50 kVA, and one power module is 100 kW in a 3U case.

Can UPS modules be replaced without switching off the load?

Yes, the power modules, bypass and monitoring module are hot-swap units. Service does not require stopping the hall.

What is the UPS efficiency in HECO mode?

In normal mode efficiency is 95.8–96%, and in HECO mode it reaches 99%.

How many HPM3300E systems can be connected in parallel?

Up to 8 systems. This gives capacity beyond the 150 kVA of a single system.

What power factor does this UPS have?

0.99 at the input and 1.0 at the output. So the rated kVA at the output equals the kW of active load.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.