Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

KSTAR HPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW

Supplied as an official KSTAR partner

A modular UPS rated up to 1200 kW per system, built from HPM3300E subrack chassis of 40–150 kVA. It runs on KLi lithium-ion battery racks, and efficiency reaches 96.5%. It is meant for server rooms, data centers and industrial sites that need high power density on a small floor area.

Power
up to 1200 kW per system; HPM3300E subrack 40–150 kVA
Parallel operation
up to 8 UPS units
Efficiency
up to 96.5%
Input voltage
138–485 V AC

Technical specifications

Powerup to 1200 kW per system; HPM3300E subrack 40–150 kVA
Parallel operationup to 8 UPS units
Efficiencyup to 96.5%
Input voltage138–485 V AC
BatteriesKLi lithium-ion racks
Maintenancemodule replacement in 5 minutes

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The system is built from modules in a chassis, so capacity is added in blocks without replacing the whole UPS. Up to eight UPS units are connected in parallel. The permissible input voltage is 138–485 V AC, so the UPS stays in mode even under deep sags and grid imbalance, without going to batteries. KLi lithium-ion racks take less space than lead-acid banks of the same capacity, which reduces the floor area for equipment. A module is replaced in 5 minutes, so recovery after a fault does not need a long shutdown.

How to choose

System capacity is set by the number of modules in the chassis, from 40 to 150 kVA on the HPM3300E. For loads up to 1200 kW a parallel system of several UPS units is assembled. If you need less power, look at the YDC3300 at 10–200 kVA (efficiency up to 95.8%, also up to 8 UPS units in parallel) or the UD at 10–80 kVA. For small systems there is the MEMOPOWER-III at 1–10 kVA. There is only one battery type here, lithium-ion racks.

Request a price and lead time

HPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW, KSTAR. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the maximum power of the HPM modular UPS?

The system reaches 1200 kW. A single HPM3300E chassis is rated 40–150 kVA.

How many UPS units can be connected in parallel?

Up to 8 UPS units work in parallel. This is how capacity or redundancy is increased.

What are the efficiency and input voltage range of the HPM?

Efficiency reaches 96.5%, and the input voltage is 138–485 V AC.

Which batteries does the HPM Lithium-ion UPS use?

KLi lithium-ion racks. They take less floor area for batteries than lead-acid ones.

How long does it take to replace a UPS module?

Replacing a module takes 5 minutes. This shortens recovery time after a module fails.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.