KSTAR HPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: HPM3300E
A modular UPS rated up to 1200 kW per system, built from HPM3300E subrack chassis of 40–150 kVA. It runs on KLi lithium-ion battery racks, and efficiency reaches 96.5%. It is meant for server rooms, data centers and industrial sites that need high power density on a small floor area.
- Power
- up to 1200 kW per system; HPM3300E subrack 40–150 kVA
- Parallel operation
- up to 8 UPS units
- Efficiency
- up to 96.5%
- Input voltage
- 138–485 V AC
Technical specifications
| Power | up to 1200 kW per system; HPM3300E subrack 40–150 kVA |
|---|---|
| Parallel operation | up to 8 UPS units |
| Efficiency | up to 96.5% |
| Input voltage | 138–485 V AC |
| Batteries | KLi lithium-ion racks |
| Maintenance | module replacement in 5 minutes |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The system is built from modules in a chassis, so capacity is added in blocks without replacing the whole UPS. Up to eight UPS units are connected in parallel. The permissible input voltage is 138–485 V AC, so the UPS stays in mode even under deep sags and grid imbalance, without going to batteries. KLi lithium-ion racks take less space than lead-acid banks of the same capacity, which reduces the floor area for equipment. A module is replaced in 5 minutes, so recovery after a fault does not need a long shutdown.
How to choose
System capacity is set by the number of modules in the chassis, from 40 to 150 kVA on the HPM3300E. For loads up to 1200 kW a parallel system of several UPS units is assembled. If you need less power, look at the YDC3300 at 10–200 kVA (efficiency up to 95.8%, also up to 8 UPS units in parallel) or the UD at 10–80 kVA. For small systems there is the MEMOPOWER-III at 1–10 kVA. There is only one battery type here, lithium-ion racks.
Request a price and lead time
HPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the maximum power of the HPM modular UPS?
The system reaches 1200 kW. A single HPM3300E chassis is rated 40–150 kVA.
How many UPS units can be connected in parallel?
Up to 8 UPS units work in parallel. This is how capacity or redundancy is increased.
What are the efficiency and input voltage range of the HPM?
Efficiency reaches 96.5%, and the input voltage is 138–485 V AC.
Which batteries does the HPM Lithium-ion UPS use?
KLi lithium-ion racks. They take less floor area for batteries than lead-acid ones.
How long does it take to replace a UPS module?
Replacing a module takes 5 minutes. This shortens recovery time after a module fails.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
UDUD three-phase online UPS 10–80 kVA
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVA
HPM3300EHPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWEREPOWER industrial transformer-based UPS 10–800 kVA 3:3
EPOWER-HEPOWER-H IGBT transformer-based UPS 10–600 kVASimilar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.