KSTAR EPOWER-L industrial UPS with isolation transformer 10–160 kVA
Supplied as an official KSTAR partner
Manufacturer: KSTAR · China · Model: EPOWER-L
An industrial online UPS rated 10–160 kVA with a built-in isolation transformer. The input and output are three-phase (3:3), and the design is made for harsh operating conditions where the load has to be galvanically separated from the grid.
- Power
- 10–160 kVA
- Phases
- 3:3
- Power factor
- up to 0.97 (input), output 0.8
- Control
- DSP
Technical specifications
| Power | 10–160 kVA |
|---|---|
| Phases | 3:3 |
| Power factor | up to 0.97 (input), output 0.8 |
| Control | DSP |
| Parallel operation | up to 6 UPS units |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
In an online scheme the load is fed through the inverter all the time, so grid sags and faults do not reach the consumer. The isolation transformer is mounted inside the UPS itself, so no separate transformer is needed in the panel. A DSP processor controls the conversion. Input power factor reaches 0.97 and output power factor is 0.8, so active power is 0.8 of the apparent power in kilovolt-amperes. Up to 6 UPS units can be connected in parallel to raise system capacity as the load grows.
How to choose
First add up the apparent power of the load in kVA and include a margin, bearing in mind the output power factor of 0.8. One unit covers 10–160 kVA, and for larger sites a parallel group of up to 6 UPS units is built. If galvanic isolation is not needed and the load does not exceed 80 kVA, look at the three-phase UD at 10–80 kVA with a power factor of 0.9. For the 10–200 kVA range and parallel operation of up to 8 UPS units, the high-frequency YDC3300 fits.
Request a price and lead time
EPOWER-L industrial UPS with isolation transformer 10–160 kVA, KSTAR. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Why does the EPOWER-L have a built-in isolation transformer?
It galvanically separates the input from the load, which is why the series is made for harsh operating conditions. No separate transformer next to the UPS is needed.
What is the power range of the EPOWER-L?
From 10 to 160 kVA, with a three-phase input and output (3:3).
How many EPOWER-L units can be run in parallel?
Up to 6 UPS units. This is how total capacity is increased when the load exceeds one unit.
What are the input and output power factors of the EPOWER-L?
Up to 0.97 at the input and 0.8 at the output. Active power in kW thus equals 0.8 of the apparent power in kVA.
What control is used in the EPOWER-L industrial UPS?
Digital control on a DSP processor.
More from KSTAR
MEMOPOWER-IIIMEMOPOWER-III single-phase online UPS 1–10 kVA
UCRUCR online UPS 6–10 kVA 3:1 rack/tower
UDUD three-phase online UPS 10–80 kVA
YDC3300YDC3300 three-phase high-frequency online UPS 10–200 kVA
HPM3300EHPM3300E modular three-phase UPS 10–150 kVA / 100 kW modules
HPM3300EHPM Lithium-ion UPS modular UPS with lithium batteries up to 1200 kW
HPM3300E-THPM3300E-T high-frequency high-power UPS 200–1000 kVA
EPOWEREPOWER industrial transformer-based UPS 10–800 kVA 3:3Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.