Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

KSTAR EP-IND-ZY industrial UPS, 10–120 kVA, 3:1, with 12-pulse rectifier

Supplied as an official KSTAR partner

The EP-IND-ZY is a transformer-type UPS rated 10–120 kVA with a three-phase input and a single-phase output (3:1). The 12-pulse rectifier and the 300–500 V AC input voltage are built for industrial networks. It is installed in the oil and gas industry, in refining, in chemicals and in industrial power engineering.

Power
10–120 kVA
Phases
3:1
Rectifier
12-pulse
Input voltage
300–500 V AC

Technical specifications

Power10–120 kVA
Phases3:1
Rectifier12-pulse
Input voltage300–500 V AC
Ingress protectionIP31

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

This is an industrial UPS of the transformer type, meaning it has galvanic isolation, unlike the transformerless models made for offices. The rectifier is 12-pulse, which reduces harmonics in the input network compared with simpler circuits. The input accepts 300–500 V AC, which matches three-phase industrial networks. IP31 means protection against solid objects and vertically falling drops, so the cabinet goes indoors, for example in an electrical room or at a control point. The rated power is chosen within 10–120 kVA according to the load, and the 3:1 scheme means a three-phase supply with a single-phase output for instrumentation and automation loads.

How to choose

The main parameter is power in kVA, selected with a margin over the total load. The 3:1 scheme is needed when the input is three-phase and the consumers are single-phase. If you need three phases at the output, look at the UD series, 10–80 kVA, with the 3:3 scheme. For small loads of 6–10 kVA with a 3:1 output there is the UCR in a rack/tower format. When choosing between them, consider the 12-pulse rectifier and the transformer of the EP-IND-ZY, which heavy industrial sites actually need.

Request a price and lead time

EP-IND-ZY industrial UPS, 10–120 kVA, 3:1, with 12-pulse rectifier, KSTAR. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which industries is the EP-IND-ZY UPS intended for?

The oil and gas industry, oil refining, chemicals and industrial power engineering. It is a transformer-type UPS rated 10–120 kVA.

What does 3:1 mean in a UPS designation?

Three phases at the input and one phase at the output. The input voltage of the EP-IND-ZY is 300–500 V AC.

Why does an industrial UPS need a 12-pulse rectifier?

It reduces the harmonics the UPS injects into the input network, compared with simpler circuits. The EP-IND-ZY has exactly a 12-pulse rectifier.

What ingress protection does the EP-IND-ZY have?

IP31. The cabinet is installed indoors.

Which UPS should I take if I need a three-phase output?

For example, the UD rated 10–80 kVA with the 3:3 scheme. The EP-IND-ZY has a single-phase output.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.